The scope of work encompassed various tasks, including site location, service identification, and weld identification, followed by mechanical excavation. We conducted the removal of existing coatings, abrasive blasting, and employed non-destructive testing (NDT) methods such as Magnetic Particle Inspection (MPI), Ultrasonic Testing (UT), as well as corrosion and mechanical damage measurements. After repairs, we ensured meticulous recoating, backfill, and reinstatement. The dig sites were located in the South East region of South Australia with dig sites located in road reserves, private lands and near other services. All digs were completed within 3 weeks and within budget, demonstrating our commitment to efficiency and quality.
location
South East South Australia
Total No. of Digs
8
Total Length of Digs
50m
Project Duration
3 Weeks
Existing Coating
Yellow Jacket
New Coating
Denso Protal 7700
Anomalies
Corrosion and Bulge
Repairs
No repairs other than new coating